Fire Inspection And Code Enforcement 7th Edition Download

Description

  1. A reference manual for both uniformed and civilian inspectors, Fire Inspection and Code Enforcement. More » (7th edition) is a comprehensive source of information. This manual educates inspectors about the principles and techniques of fire prevention and life-safety inspection and code compliance.
  2. Fire Inspection and Code Enforcement, 7th Edition Chapter 6 — Building Construction: Components Inspector II.

Fire Inspection And Code Enforcement 7th Edition Download Windows 10

A reference manual for both uniformed and civilian inspectors, Fire Inspection and Code Enforcement (7th edition) is a comprehensive source of information. This manual educates inspectors about the principles and techniques of fire prevention and life-safety inspection and code compliance. It addresses NFPA® 1031, Standard for Professional Qualifications for Fire Inspector and Plan Examiner, Levels I and II of the 2009 edition. In addition, this manual has also been written to meet the learning objectives of the Fire and Emergency Services Higher Education (FESHE) Principles of Code Enforcement course. This is a reference manual for both uniformed and civilian inspectors.

Table of Contents

1. Duties and Authority
2. Standards, Codes, and Permits
3. Fire Behavior
4. Construction Types and Occupancy Classifications
5. Building Construction: Materials and Structural Systems
6. Building Construction: Components
7. Components
8. Water Supply Distribution Systems
9. Water-Based Fire-Suppression Systems
10. Special-Agent Fire-Extinguishing Systems and Extinguishers
11. Fire Detection and Alarm Systems
12. Fire Hazard Recognition
13. Site Access
14. Hazardous Materials: Descriptions and Identification Methods
15. Hazardous Materials: Storing, Handling, Dispensing, Transporting,
Using, and Disposing
16. Plans Review and Field Verifications
17. Inspection Procedures

Fire Inspection and Code Enforcement, 8th Edition and Exam Prep (Print) Manual and Print Exam Prep Pkg. Item #: 36306. $117.00 $105.30.

Print

This title is currently unavailable on myPearsonStore.
We recommend Fire Inspection and Code Enforcement, 8th Edition as a replacement.

30 Questions | By Tribecca09 | Last updated: Jan 23, 2013
Settings

Fire Inspection And Code Enforcement If…

Fire inspection code enforcement guide

Fire Inspection And Code Enforcement 7th Edition Download Pc

Success! A copy of this quiz is in your dashboard.

Fire Inspection And Code Enforcement 7th Edition Download 2017

  • A properly designed and maintained means of egress cannot function effectively when:
    • The means of egress contains smoke

    • Active fire-protection systems are in use

    • The total occupant load has been exceeded.

  • During annual inspections, an inspector ensures that conditions have not changed in the occupancy, use, or exit requirements for the structure and:
    • Monitors the condition of existing means of egress

    • Ensures the structure matches the surrounding buildings

    • Documents that the structure has adequate hazard insurance

    • A.
    • B.
    • C.
  • 4.
    • A.
    • B.
    • C.
  • 5.
    • A.
    • B.
    • C.
  • 6.
    What is the minimum width and height of a public way?
    • 5 feet

    • 10 feet

    • 15 feet

  • Which of the following is an example of an exit access?
    • Horizontal exit

    • Unenclosed ramp or stairs

    • Doors at ground level that lead directly to the outside of the building

  • Which of the following is an example of an exit?
    • Are of refuse

    • Unenclosed ramp or stairs

    • Doors at ground level that lead directly to the outside of the building

    • A.

      The exit and exit access must be at least 50% clear of obstructions

    • Only movable furnishings or decorations are allowed in the exit and exit access.

    • No furnishings or decorations may be allowed to obstruct or conceal an exit or exit access

    • A.
    • B.
    • C.
  • 11.
    • A.
    • B.
    • C.
  • 12.
    Which of the following components are designed to connect an interior exit stair to an exit door on the exterior of the structure?
    • Vertical exits

    • Horizontal exits

    • Exit passageways

    • A.
    • B.

      Alert emergency personnel of the exact location of the fire

    • Separate occupants from fire, smoke, and other hazardous elements during escape

  • In new buildings, each of the model code organizations requires that doors serving as a component of a means of egress be at least_______wide.
    • 18 inches

    • 24 inches

    • 36 inches

  • When do the exit requirements for a building take on a higher level of significance and must meet additional exiting system requirements?
    • If 30 or more people are in a room or occupancy

    • If 40 or more people are in a room or occupancy

    • If 50 or more people are in a room or occupancy

    • A.

      Open and close by remove control to allow easy access

    • Provide energy savings during times the building is in use

    • Close automatically to provide a smoke or fire barrier in a fire-barrier wall

  • The fire-resistance rating of walls is based on the type of occupancy, type of building construction, and:
    • Whether the building has easily accessible fire extinguishers

    • Whether or not the building has an automatic sprinkler system

    • What type of hazard insurance is carried by the building owner

  • If the ceiling is part of the fire-resistance-rated walls, the ceiling:
    • Must have the same rating as the walls

    • Must have a higher rating than the walls

    • Can have a lower rating than the walls

    • A.
    • B.
    • C.
  • 20.
    • A.

      Handrails are required on both sides of the stairs

    • Stairways must be at least 60 inches wide.

    • Each flight of stairs between landings must be no longer than 18 feet

  • Ramps become common elements in many occupancies in the US with the adoption of the:
    • Equal Access Law in 2000

    • Americans with Disabilities Act in 1990

    • United States standard building codes

    • A.

      They cannot be used as a means of egress in any structure

    • They may be used as part of a mean of egress in new construction

    • They may NOT be used as part of a means of egress in new construction

  • Fire escapes slides must be of an approved type and rated at one exit unit per slide with a rated capacity of ______ persons.
    • 30

    • 50

    • 60

  • The illumination and marking requirements of exits vary with:
    • Each model code organization

    • Each type of occupancy classification

    • The number of occupants and the time of day

  • Exit markings must be positioned so that NO point in the exit access is more than _____ from the nearest visible sign.
    • 100 feet

    • 150 feet

    • 200 feet

    • A.
    • B.
    • C.
  • 27.
    When should the auxiliary power system and emergency lighting system be tested?
    • Weekly

    • Every six months

    • Monthly and annually

  • Which of the following terms refers to the total number of persons who may occupy a building or portion of it at any one time?
    • Building capacity

    • Occupant load

    • Maximum area per person

  • The occupant load is determined by dividing the net floor area by the:
    • Gross floor area

    • Number of exits

    • Area per person (factor)

    • A.
    • B.
    • C.